The selection of a solenoid valve should first follow the four principles of safety, reliability, applicability, and economy, and then be selected based on six aspects of on-site working conditions (i.e. pipeline parameters, fluid parameters, pressure parameters, electrical parameters, action mode, and special requirements).
Selection basis:
1. Select the solenoid valve according to pipeline parameters: diameter specification (i.e. DN), interface method
1) Determine the diameter (DN) size according to the on-site pipeline inner diameter size or flow requirements;
2) Interface method, generally > DN50 should choose a flange interface, ≤ DN50 can be freely selected according to user needs.
2. Select the material and temperature group of the solenoid valve according to the fluid parameters
1) Corrosive fluid: It is advisable to use corrosion-resistant solenoid valves and all-stainless steel; Edible ultra-clean fluid: It is advisable to use food-grade stainless steel solenoid valves;
2) High-temperature fluid: It is necessary to select solenoid valves made of high-temperature resistant electrical materials and sealing materials, and to select piston-type structures;
3) Fluid state: There are gaseous, liquid or mixed states, especially when the diameter is greater than DN25, it must be distinguished;
4) Fluid viscosity: Usually it can be selected arbitrarily below 50cSt. If it exceeds this value, a high-viscosity solenoid valve must be selected.
3. Select the principle and structural variety of the solenoid valve according to the pressure parameters
1) Nominal pressure: This parameter has the same meaning as other general valves and is determined according to the nominal pressure of the pipeline;
2) Working pressure: If the working pressure is low, the direct-acting or step-by-step direct-acting principle must be selected; when the minimum working pressure difference is above 0.04Mpa, direct-acting, step-by-step direct-acting, and pilot-operated types can be selected.
4. Electrical selection: AC220V and DC24 should be preferred as voltage specifications.
5. Choose according to the duration of continuous working: normally closed, normally open, or continuously powered
1) When the solenoid valve needs to be opened for a long time and the duration is longer than the closing time, the normally open type should be selected;
2) If the opening time is short or the opening and closing time is not much, the normally closed type should be selected;
3) However, for some working conditions used for safety protection, such as furnace and kiln flame monitoring, the normally open type cannot be selected, and the long-term powered type should be selected.
6. Select auxiliary functions according to environmental requirements: explosion-proof, check, manual, waterproof fog, water spray, diving.