The solenoid valve is a solenoid coil that generates magnetic attraction to overcome the pressure of the spring to drive the valve core to move. It is just a solenoid coil, with a simple structure and low price. It can only realize switching;
The electric valve drives the valve stem through an electric motor to drive the valve core to move. The electric valve is divided into (shut-off valve) and regulating valve. The shut-off valve is a two-position operation, that is, fully open and fully closed. The regulating valve is installed with an electric valve positioner on it, and the valve is dynamically stabilized in one position through closed-loop regulation.
Comparison of the uses of electric valves and solenoid valves
Solenoid valve: used for switch control of liquid and gas pipelines, which is a two-position DO control. Generally used for the control of small pipelines.
Electric valve: used for analog quantity adjustment of the flow rate of liquid, gas and wind system pipeline media, which is AI control. Electric valves can also be used for two-position switch control in the control of large valves and wind systems.
Solenoid valve: can only be used as a switch quantity, which is DO control, can only be used for small pipeline control, and is common in pipelines of DN50 and below.
Electric valve: can have AI feedback signal, can be controlled by DO or AO, and is more common in large pipelines and wind valves.
1. Switching form:
The solenoid valve is driven by a coil and can only be opened or closed. The action time when switching is short.
The electric valve is generally driven by a motor. The opening or closing action requires a certain amount of time to complete the analog quantity, which can be adjusted.
2. Working nature:
The solenoid valve generally has a very small flow coefficient and a very small working pressure difference. For example, the flow coefficient of a 25-caliber solenoid valve is much smaller than that of a 15-caliber electric ball valve. The solenoid valve is driven by a solenoid coil and is more easily damaged by voltage shock. It is equivalent to the function of a switch, which is the two functions of opening and closing.
The electric valve is generally driven by a motor and is more resistant to voltage shock. The solenoid valve is fast opening and closing, and is generally used in places with small flow and small pressure. The electric valve is the opposite. The opening of the electric valve can be controlled, and the states are open, closed, half open and half closed. It can control the flow of the medium in the pipeline, but the solenoid valve cannot meet this requirement.
The solenoid valve can generally be reset when the power is off. If the electric valve needs such a function, a reset device needs to be added.
3. Applicable process:
Solenoid valves are suitable for some special process requirements, such as leakage, special fluid media, etc., and are more expensive.
Electric valves are generally used for adjustment, and there are also switch quantities, such as: fan coil end.
The difference between solenoid valve and electric valve
Dec 05, 2024
Leave a message